Your reliable automation partner

Solutions for building, industrial and medical automation
Safety, savings, control and comfort, all in one

Web BACnet Router – C4.WBR.02

Web BACnet Router – C4.WBR.02

  • Available ports: 1x Ethernet port, 4 x RS485 ports
  • Interchangeable ports for BACnet and Modbus
  • Up to 32 of Bacnet/IP and Modbus/IP layers is supported through one Ethernet physical layer. Routing table is flexible and may contain 65533 entries
  • Device supports time synchronization
  • BACnet application layer supports the following standard BACnet objects: 1. Device, 2. Analog Input, Analog Output, Analog Value, 3. Binary Input, Binary Output, Binary Value, 4. Multi -State Input, Multi -State Output and Multi -State Value, 5. File, 6. Additional BACnet objects by software updates
  • Application layer relies on SQLite database, so that data collected from the networks are available even in case of communication loss
  • Modbus application layer supports the following functions:1. Read Coils, Read Discrete Inputs, 2. Read Holding Registers, Read Input Registers, 3. Write Single Coil, Write Single Register, 4. Write Multiple Coils, Write Multiple Registers, 5. Read File Record, Write File Record
  • RTC (real-time clock) with backup power supply
  • LED indicators for device and communication status
Category:

Description

WBR is a BACnet routerdesigned for wide range of building automation and guest room management system tasks with the additional BACnet/Modbus bridge functionality. Furthermore, this device contains application layer with compact SQL database, accessible through a web service. Configuration is done through web interface or the USB port. BACnet routing is established through the Ethernet port and four RS485 ports. Each serial port can be used as BACnet MSTP or Modbus serial port. Up to 32 of Bacnet/IP and Modbus/IP layers are supported through one Ethernet physical layer. Routing table is flexible and may contain up to 65533 entries. Both serial (RTU and ASCII) and IP Modbus are supported.

BACnet application layer supports the following standard BACnet objects:

  • Device
  • Analog Input, Analog Output, Analog Value
  • Binary Input, Binary Output, Binary Value
  • Multi -State Input, Multi -State Output and Multi -State Value
  • File
  • Additional BACnet objects by software updates

Modbus application layer supports the following functions:

  • Read Coils, Read Discrete Inputs
  • Read Holding Registers, Read Input Registers
  • Write Single Coil, Write Single Register
  • Write Multiple Coils, Write Multiple Registers
  • Read File Record, Write File Record

BACnet Modbus Gateway Functionality

Modbus is an older communication protocol, still used in a wide variety of devices and systems. WBR offer simple interface for defining mappings of Modbus devices and data points to BACnet devices and objects. Those mappings can be easily copied to other WBRs, which streamlines system integration. All standard Modbus data types are supported.

Additional information

Electrical Specifications

title

Power supply

24 VAC/VDC, 5 W

Communication Channels

title

Ethernet

10/100BASE-TX

4 x RS485

Up to 32 devices on bus without usage of repeaters

USB

USB device, USB mini connector service port

Hardware Resources

title

Microprocessor

ARM9 (32bit architecture, 400 MIPS)

RAM memory

128 MB

Flash memory

512 MB

RTC

With backup power supply

Additional Specifications

title

Operating temperature

-10.. +70°C

Storage temperature

-40.. +85℃

Operating humidity

max 95% r.H., no condensation

Protection degree

IP20

Mounting

DIN rail, for indoor use only

Weight
250 g
Dimensions
107.6 x 90 x 62.2 mm

Downloads

Documentation

Technical Data Sheet for Compact PLC Web BACNet Router - C4.WBR.02

Web BACnet Router - C4.WBR.02

 

User manual for Compact PLC Web BACNet Router - C4.WBR.02

User manual for Compact PLC Web BACnet Router - C4.WBR.02

 

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

Software versions
NOTICE: all software versions older that 1.1.8 must be upgraded first to 1.1.8, and then to the latest version.

WBR-1.1.12.

WBR-1.1.11.

WBR-1.1.10.

WBR-1.1.9.

WBR-1.1.8.

Drivers

x32 Windows RNDIS driver

x64 Windows RNDIS driver, pre-Win8

x64 Windows RNDIS driver, Win8